Energy

Energy

Functionality Hardware:
Mechanical Data:
  • Variable design housing approx. 175 x 135 x 50mm
  • LCD Display with pictograms
  • Centralized operation with 4 pressure keys
Outputs:
  • 2 Electronic outputs 230V/AC 1A, Cos.= 0,9; with zero crossing switch, fuse protection 3A/MT
  • 1 x output for pump speed control
  • 1 x output for auxilliary heating
  • Connection: Connectors grid 5,0mm
Inputs:
  • 4 Temperature sensor inputs for PT1000 sensors
  • 1 Digital Input for potential free, external contact
  • Connection: Connectors Grid 5,0mm (optional flow meter)

 

Functionality Software:
Functions:
  • Solar circuit control by temperature difference controller
  • Reheat function (auxilliary heating)
  • Collector protection
  • System protection
  • Re-cooling function (holiday mode)
  • Energy yield measurement (with optional flow meter)
  • Sensor monitoring
  • Flow monitoring
SOLAREG II Specifications ENERGY

Electronic temperature differential controller (sensing control), 4 inputs, 2 outputs, independently mounted, continuous operation.

System Layout Schematic

1 Collector, 1 Storage Tank

 Delivery
  • 1 pcs. Controller device, sequential packing
  • 1 pcs. User manual, English
  • 2 pcs. PT1000 Store Sensors PVC, 2,0m
  • 1 pcs. PT1000 Collector Sensor Silicon, 1,5m

Energy

Material100% recyclable ABS-housing for wall installation
Measures L x W x D in mm. weight175 x 134 x 56 ca. 360 g
Protection classIP20 according to DIN 40050, IEC 529, VDE 0470, EN 60529
Operating voltageAC 230 Volt, 50 Hz, -10...+15%
Interference gradeN according to VDE 0875
Max. conductor cross-section 230V-connections2,5 mm² fine-strand/single-wire
Temperature sensor / temperature rangePTF6 - 25°C - 200°C PT1000, 1,000 kΩ at 0°C
Output - 1 For circulation pump (speed control)230V/AC 1A, Cos ϕ = 0,9;
Output - 2 For circulation pump (speed control)230V/AC 1A, Cos ϕ = 0,9;
Testing voltage4 kV 1 min according to VDE 0631
Switching voltage Capability per one switch output Total capability of all outputs230V~ / 1A / ca. 230VA for cos ϕ = 0,7-1,0 2A / ca. 460VA maximal
Fuse protectionfine-wire fuse 5 x 20mm, 2A/T (2 amperes, slow)
Recommended flow transmitterPVM 1,5/90 1500l/h, Tmax >=90°C, 10l/ impuls
Operating temperature0 ... + 50°C
Storing temperature-10 ... + 65°C
You can navigate above
between our 4 divisions.