| Gross Collector Area | 2.08m² |
| Absorber area | 1.91m² |
| Height | 2000mm |
| Width | 1039mm |
| Depth | 99mm |
| Empty weight | 38kg |
| Fluid content | 1.15 litres |
| Connections | 18mm/can adapt to ½" or ¾" |
| Collector glazing | 4mm, Solar safety float glass |
| Absorber | Laser welded aluminium absorber, Bluetec Eta Plus Vacuum coating / Copper harp |
| Max operating pressure | 6 Bar (pressure tested to 9 bar) |
| Stagnation temperature | 197°C |
| Flow rate recommendation | Minimum 0.6 litre per min / m² |
| Minimum inclination | 15° |
| Maximum collectors piped in series | 8. However, there is no limit to the amount of collectors which can be mounted together |
| Absorption | 95% |
| Emission | 5% |
| Minimum output | 525 kwh/m²a |
| Conversion Factor ƞ0 | 0.783 |
| Heat Transfer Coefficient a1 | 3.95 W/m²K |
| Temperature depending coefficient heat transfer a2 | 0.008 W/m²K |