Primos 600

Primos 600

Functionality Hardware:
Mechanical Data:
  • Variable design housing approx. 176 x 162 x 44mm,
  • protection class IP30, light grey, cover plate Prozed 
  • Illuminated LCO display with pictograms, 60 x 45mm,
  • Centralized operation with 4 pressure keys
  • Piezo-acoustic signal transmitter
Outputs 230V AC:
  • 3 electronic output 230V/AC, min. 10mA, max. 1A, cos.
  • 0,9; with zero crossing switch, fuse protection 2AIT
  • RPM control by block modulation
  • 2 x output for pump speed control
  • 1 x output for potential heating / cooling function
  • Connections: Screw-type terminals, connectors grid 5,0mm
Outputs low voltage, to control high-efficiency pumps:
  • 2 electronic control output, control signal configurable by software between PWM-digital signal approx. 10V, and analogue signal 0-10V, +/-3%
  • Connections: Screw-type terminals, connectors grid 5,0mm
Outputs potential-free: (auxilliary heating)
  • 1 relay output with potential-free make contact, also suitable for protective low voltage, max. 250V AC /1A
  • Connections: Screw-type terminals, connectors grid 5,0mm
Inputs:
  • 6 temperature inputs for PT1 000 sensors
  • 1 digital input for flow transmitter (paddle-wheel flow transmitter)
  • 1 input for radiation sensor
  • Connections: Screw-type terminals, connectors grid 5,0mm
Interfaces
Grundfos VFS-sensor:
  • 1 interface for Grundfos VFS -sensor incl. 5V supply voltage
  • Connections: Screw-type terminals, connectors grid 5,0mm
Micro-SD card:
  • 1 Micro-SD card slot

Prozeda-data bus:
  • 1 Prozeda data bus interface

Functionality Software:
  • Temperature difference controller with multiple system diagrams, 1 - 2 collectors, 1 - 2 storage tanks
  • Real time clock
  • Re-cooling function (holiday mode)
  • Loading time storage tank
  • System protection
  • Collector protection
  • Pump protection
  • Anti-freeze protection
  • Recording solar radiation
  • Energy yield measurement
  • adjustable control time during o. while priority charging
  • Loading of second-tier storage tank with logical
  • backspace to prior storage tank (holding time adjustable)
  • Parallel charging of storage tanks
  • Heat exchanger protection
  • Target temperature operation
  • “Shut-off pool” (storage tank can be deactivated)
  • Parallel pump operation
  • Drain-Back function
  • RPM control
  • Sensor monitoring
  • Manual operation
  • Flow monitoring
  • Tube collector with adjustable enable time slot
  • Acoustical error indications
  • 4 Multifunction controller packages (Heating, Cooling, delta T, free sensor selection, 12 adjustable time slots for additional functions)
  • Data logging with recording function
  • System specific parameter setup
  • Firmware update
  • Possibility of controllers networking
  • Remote visualisation from any distance (conexio)
  • Remote control
Delivery
  • 1 piece controller device, sequential packing
  • 1 piece user manual, English
  • 1 data CD-Rom (contains controller specific additional information)
  • 1 piece assembly kit
  • 2 piece PT1000 Store sensor, with PVC-cable, length 2000mm, brass sleeve 6x25mm
  • 2 piece PT1000 Collector sensor, with silicon cable, length 1500mm, brass sleeve 6x25mm

Primos 600

Housing Material100% recyclable ABS housing
Dimensions L x W x D in mm176 × 162 × 44
Protection classIP30 according to DIN 40050, EN 60529
Operating voltage:AC 230 voltage, 50 Hz, –10 to +15%
Power consumption< 2 W
Max. line cross-section for 230 V connections2.5 mm² finely stranded/single core
Inputs 1–4 (protected by varistors)For temperature sensors PT 1000 (1 kΩ at 0 °C)
Other inputsVFS (Vortex flow sensor)
Measuring range (temperature)–30 °C to +250 °C
InterfacesRS 485 for Prozeda bus
Output R1 - R3Electronic semiconductor relay (Triac) with zero-cross switch, opto-decoupled, 230 V AC, 50 Hz, min. 10 mA, max. 150 W, with cos ϕ >=0.9
Total output of all outputsMax. 300 W
Output R0Relay, potential-free normally open contact, max. 250 V AC / 1 A, also suitable for protective extra-low voltage
Control output for HE pumpPWM signal: 1kHz, ViL < 0.5 V DC, ViH > 9 V DC, 10 mA max. Analog signal: 0 - +10 V DC +/– 3%, 10 mA max.
DisplayBacklit LCD display
Type 1 actionType 1.B and type 1.Y
Software classA
ProtectionMicrofuse 5 × 20 mm, 2 A/T (2 ampere, slow)
Ambient temperature:0 to +40 °C
Storage temperature-10 to +60 °C
You can navigate above