SunSpeed
domestic hot water cylinders are designed
for use with solar panels. The heat exchangers
are purpose designed for this application
because: -
(a) The primary flow temperature from
these sources will normally be significantly
lower than from conventional heat sources
e.g. gas boilers. Therefore heat exchangers
with large surfaces areas will be necessary
to transfer the heat at low temperature
differences.
(b) A second heat exchanger for conventional
heat sources e.g. gas boilers will often
be required. In this case the solar panel
heat exchanger must be of a compact design
and capable of being fitted very low down
in the cylinder.
Performance
The ‘SunSpeed’ heat exchanger
is designed to heat the cylinder water content
from 10°C to 49°C in one hour with
a constant primary flow temperature of 55°C.
The heat exchanger for use with conventional
heat sources (e.g. a gas boiler) in SunSpeed
2 is rated to give the recovery time under
30 minutes as specified in BS1566.