Gledhill Sunspeed 2 - Twin Coil Vented
SunSpeed domestic hot water cylinders are designed for use with solar panels. The heat exchangers are purpose designed for this application because: -

(a) The primary flow temperature from these sources will normally be significantly lower than from conventional heat sources e.g. gas boilers. Therefore heat exchangers with large surfaces areas will be necessary to transfer the heat at low temperature differences.

(b) A second heat exchanger for conventional heat sources e.g. gas boilers will often be required. In this case the solar panel heat exchanger must be of a compact design and capable of being fitted very low down in the cylinder.
Performance
The ‘SunSpeed’ heat exchanger is designed to heat the cylinder water content from 10°C to 49°C in one hour with a constant primary flow temperature of 55°C.

The heat exchanger for use with conventional heat sources (e.g. a gas boiler) in SunSpeed 2 is rated to give the recovery time under 30 minutes as specified in BS1566.

SunSpeed
Heat exchanger specification
The heat exchanger in a SunSpeed cylinder designed for SOLAR is manufactured from ‘Integron’ integrally finned copper tube and is only suitable for pumped circuits.

In a SunSpeed 2, the heat exchanger i.e. coil for use with a conventional heat source is manufactured in either 22mm or 28mm plain copper tube to meet the requirements of BS1566 and Part L of the Building Regulations